OMRON
D4BL-1CRG-A
Guard lock safety-door switch with orange/green LED indicator unit (10-115Vac/Vdc) - OMRON / STi (D4BL series) - Holding force min. 700N - Power-to-lock - 1NC/1NO (slow-action; door open/closed detection) + 1NC (slow-action; lock monitor) contacts - 24Vdc control voltage - 2 x term. wiring chamber with Pg13.5 condt. outlets - IP67 - rated for -10...+55°C ambient - equivalent to D4BL1CRGA
Please add this item to cart to request a quote or contact us at [email protected] for product availability.
Brand
SKU
D4BL-1CRG-A
Online Price
$600.00
Please add this item to cart to request a quote or contact us at [email protected] for product availability.
D4BL-1CRG-AOMRON - D4BL series
Description
Guard lock safety-door switch with orange/green LED indicator unit (10-115Vac/Vdc) - OMRON / STi (D4BL series) - Holding force min. 700N - Power-to-lock - 1NC/1NO (slow-action; door open/closed detection) + 1NC (slow-action; lock monitor) contacts - 24Vdc control voltage - 2 x term. wiring chamber with Pg13.5 condt. outlets - IP67 - rated for -10...+55°C ambient - equivalent to D4BL1CRGA
Specifications
Primary brand
OMRON
Secondary brand
STi
Main function
Door lock (Tongue-operated)
Product series / family name
D4BL series
Network frequency
50/60 Hz
Functions
Guard lock safety-door switch
Solenoid lock / mechanical release
Solenoid lock / mechanical release
Design
orange/green LED indicator unit (10-115Vac/Vdc)
Distance
20mm min. direct opening travel (EN 60947-5-1)
2 x 2mm min. contact gap
2 x 2mm min. contact gap
Resistance (Ω)
50mΩ max. (contact resistance)
100mΩ min. (insulation resistance; at 500Vdc)
100mΩ min. (insulation resistance; at 500Vdc)
Frequency
30 operations/minute max.
50/60Hz
50/60Hz
Rated current
10A (carry current; A300)
100A (conditional short-circuit; EN60947-5-1)
20A (Ith enclosed thermal current; EN 60547-5-1)
3A (AC-15)
60A (make current; at 120Vac; A300)
6A (break current; at 120Vac; A300)
30A (make current; at 240Vac; A300)
3A (break current; at 240Vac; A300)
3A (AC-15)
0.27A (DC-13)
100A (conditional short-circuit; EN60947-5-1)
20A (Ith enclosed thermal current; EN 60547-5-1)
3A (AC-15)
60A (make current; at 120Vac; A300)
6A (break current; at 120Vac; A300)
30A (make current; at 240Vac; A300)
3A (break current; at 240Vac; A300)
3A (AC-15)
0.27A (DC-13)
Rated operating voltage (Ue)
(AC-15) 115 V
Rated voltage (AC)
120Vac (A300; 60A make current)
240Vac (A300; 30A make current)
240Vac (A300; 30A make current)
Rated impulse voltage (Uimp)
(between terminals of same polarity) 4 kV
(between terminals of different polarity) 4 kV
(between each terminal and ground) 4 kV
(between solenoid and ground) 2.5 kV
(between terminals of different polarity) 4 kV
(between each terminal and ground) 4 kV
(between solenoid and ground) 2.5 kV
Rated insulation voltage (Ui)
(EN60947-5-1) 300 V
Connection type
2 x term. wiring chamber with Pg13.5 condt. outlets
Control Voltage (DC)
24Vdc (solenoid)
Protection functions
Class I electric shock protection (with ground terminal)
Leakage current
1mA (LED) mA
Speed
0.05...0.5m/s operating speed
Operating mode
Power-to-lock
Number of Normally Open (NO) circuits
1 NO Pole(s)
Number of Normally Closed (NC) circuits
2 NC Pole(s)
Contacts type
1NC/1NO (slow-action; door open/closed detection) + 1NC (slow-action; lock monitor)
Degree of protection
IP67
Ambient air temperature for operation
-10...+55 °C
Visual position indicator
Orange ; Green
Current consumption
300mA (solenoid)
Operating force
(Direct opening force) 19.61 N
Force
19.61N min. direct opening force (EN 60947-5-1)
Electrical durability (with load)
(10A resistive load at 250Vac) min. 500 000 operations
Mechanical durability (at no load)
min. 1 000 000 operations
Rated power
(make; A300) 7200 VA
(break; A300) 720 VA
(break; A300) 720 VA
Order code / Manufacturer SKU
D4BL-1CRG-A
Manufacturer product status
Commercialized
Equivalent to
D4BL1CRGA
EAN code
4548583322271
Compliant with standard(s)
EN ISO 14119 - Type 2 - low level coded
EN 60947-5-1 (certified direct opening)
GS-ET-19
GB/T 14048.5
Vibration resistance - 10 to 55 Hz Single amplitude of 0.35mm
Shock resistance - 1000m/s2 min. (destruction)
Shock resistance - 300m/s2 min. (malfunction)
UL 508
CAN/CSA C22.2 No.14
EN 60947-5-1 (certified direct opening)
GS-ET-19
GB/T 14048.5
Vibration resistance - 10 to 55 Hz Single amplitude of 0.35mm
Shock resistance - 1000m/s2 min. (destruction)
Shock resistance - 300m/s2 min. (malfunction)
UL 508
CAN/CSA C22.2 No.14
Benefits
Auxiliary release key ensures easy maintenance and unlocks the door in the case of a power failure.
Die-cast aluminium body incorporating a switch box with degree of protection satisfying IP67; UL; and CSA TYPE6P; 13.
Equipped with a horizontal and vertical conduit outlet.
Models incorporating easy-to-see indicators for monitoring and those using an adjustable Operation Key for a swinging door are available.
The mounting direction of the head can be changed to allow the Operation Key to be inserted from four directions.
Die-cast aluminium body incorporating a switch box with degree of protection satisfying IP67; UL; and CSA TYPE6P; 13.
Equipped with a horizontal and vertical conduit outlet.
Models incorporating easy-to-see indicators for monitoring and those using an adjustable Operation Key for a swinging door are available.
The mounting direction of the head can be changed to allow the Operation Key to be inserted from four directions.
Location of origin
Japan
Mechanical withstand
(holding force) min. 700 N
Degree of pollution
3 (as per EN60947-5-1)
Insulation material
Class B (to 130°C; solenoid)
Application type
Four mounting directions possible (right-side mounting at shipping)