OMRON
D4F-302-1R
Complete small safety limit switch with roller plunger (metal roller) + direct opening mechanism - vertical cabl. pull-outing direction - OMRON / STi (D4F series) - 2NC+2NO (slow-action) contacts - Pre-wired with 1m cabl. terminated with bare end flying leads - IP67 - Metal roller - rated for -30...+70°C ambient - equivalent to D4F3021R
Please add this item to cart to request a quote or contact us at [email protected] for product availability.
Brand
SKU
D4F-302-1R
Online Price
$160.00
Please add this item to cart to request a quote or contact us at [email protected] for product availability.
D4F-302-1ROMRON - D4F series
Description
Complete small safety limit switch with roller plunger (metal roller) + direct opening mechanism - vertical cabl. pull-outing direction - OMRON / STi (D4F series) - 2NC+2NO (slow-action) contacts - Pre-wired with 1m cabl. terminated with bare end flying leads - IP67 - Metal roller - rated for -30...+70°C ambient - equivalent to D4F3021R
Specifications
Primary brand
OMRON
Secondary brand
STi
Main function
Safety limit switch
Product series / family name
D4F series
Network frequency
50/60 Hz
Functions
Complete small safety limit switch
Design
roller plunger (metal roller)
direct opening mechanism
vertical cabl. pull-outing direction
direct opening mechanism
vertical cabl. pull-outing direction
Distance
2 x 2mm min. contact gap
Resistance (Ω)
300mΩ max. (contact resistance; with 1m cable)
500mΩ max. (contact resistance; with 3m cable)
700mΩ max. (contact resistance; with 5m cable)
100mΩ min. (insulation resistance; at 500 VDC)
500mΩ max. (contact resistance; with 3m cable)
700mΩ max. (contact resistance; with 5m cable)
100mΩ min. (insulation resistance; at 500 VDC)
Frequency
120 operations/minute (mechanical)
30 operations/minute (electrical)
50/60Hz
30 operations/minute (electrical)
50/60Hz
Rated current
2.5A (carry current; C300)
2.5A (carry current; Q300)
100A (conditional short-circuit; EN60947-5-1)
2.5A (Ith thermal current; EN 60547-5-1)
0.75A (AC-15)
0.27A (DC-13)
15A (make current; at 120Vac; C300)
1.5A (break current; at 120Vac; C300)
7.5A (make current; at 240Vac; C300)
0.75A (break current; at 240Vac; C300)
0.55A (make current; at 125Vdc; Q300)
0.55A (break current; at 125Vdc; Q300)
0.27A (make current; at 250Vdc; Q300)
0.27A (break current; at 250Vdc; Q300)
4mA (resistive load; at 24Vdc; 4 circuits; N level reference value)
3A (AC-15)
0.27A (DC-13)
2.5A (carry current; Q300)
100A (conditional short-circuit; EN60947-5-1)
2.5A (Ith thermal current; EN 60547-5-1)
0.75A (AC-15)
0.27A (DC-13)
15A (make current; at 120Vac; C300)
1.5A (break current; at 120Vac; C300)
7.5A (make current; at 240Vac; C300)
0.75A (break current; at 240Vac; C300)
0.55A (make current; at 125Vdc; Q300)
0.55A (break current; at 125Vdc; Q300)
0.27A (make current; at 250Vdc; Q300)
0.27A (break current; at 250Vdc; Q300)
4mA (resistive load; at 24Vdc; 4 circuits; N level reference value)
3A (AC-15)
0.27A (DC-13)
Rated operating voltage (Ue)
(AC-15) 240 V
(DC-13) 250 V
(DC-13) 250 V
Rated Voltage (DC)
125Vdc (Q300; 0.55A make current)
250Vdc (Q300; 0.27A make current)
250Vdc (Q300; 0.27A make current)
Rated voltage (AC)
120Vac (C300; 15A make current)
240Vac (C300; 7.5A make current)
240Vac (C300; 7.5A make current)
Rated impulse voltage (Uimp)
(between terminals of same polarity) 2.5 kV
(between terminals of different polarity) 4 kV
(between each terminal and non-current carrying metallic parts) 4 kV
(between terminals of different polarity) 4 kV
(between each terminal and non-current carrying metallic parts) 4 kV
Rated insulation voltage (Ui)
250 V
Connection type
Pre-wired with 1m cabl. terminated with bare end flying leads
Protection functions
Class I electric shock protection (with ground terminal)
Speed
1...500mm/s operating speed (D4N-1120)
Number of Normally Open (NO) circuits
2 NO Pole(s)
Number of Normally Closed (NC) circuits
2 NC Pole(s)
Contacts type
2NC+2NO (slow-action)
Degree of protection
IP67
Material
Metal roller
Ambient air temperature for operation
-30...+70 °C
Electrical durability (with load)
(4mA resistive load at 24Vac; 4 circuits) min. 1 000 000 operations
(1A resistive load at 125Vac; 2 circuits / 4mA resistive load at 24Vdc; 2 circuits) min. 150 000 operations
(1A resistive load at 125Vac; 2 circuits / 4mA resistive load at 24Vdc; 2 circuits) min. 150 000 operations
Mechanical durability (at no load)
min. 10 000 000 operations
Rated Voltage (DC)
24 V
Rated power
(make; C300) 1800 VA
(break; C300) 180 VA
(make-break; Q300) 69 VA
(break; C300) 180 VA
(make-break; Q300) 69 VA
Order code / Manufacturer SKU
D4F-302-1R
Manufacturer product status
Commercialized
Equivalent to
D4F3021R
EAN code
4548583322271
Compliant with standard(s)
EN ISO 14119
EN 60947-5-1 (certified direct opening)
GS-ET-15
GB/T 14048.5
EN 50047
EN 60204-1
Vibration resistance - 10 to 55 Hz Single amplitude of 0.75mm
Shock resistance - 1000m/s2 min. (destruction)
Shock resistance - 300m/s2 min. (malfunction)
UL 508
CAN/CSA C22.2 No.14
EN 60947-5-1 (certified direct opening)
GS-ET-15
GB/T 14048.5
EN 50047
EN 60204-1
Vibration resistance - 10 to 55 Hz Single amplitude of 0.75mm
Shock resistance - 1000m/s2 min. (destruction)
Shock resistance - 300m/s2 min. (malfunction)
UL 508
CAN/CSA C22.2 No.14
Benefits
An incredibly small limit switch with a direct opening mechanism (four-contact construction model).
High-sensitivity safety limit switch.
Built-in switches with two- or four-contact construction are available.
Degree of protection -- IP67
Conforms to EN115-1; EN81-1 and EN81-2. (slow-action models only)
Certified standards -- UL; EN (TUV); and CCC
High-sensitivity safety limit switch.
Built-in switches with two- or four-contact construction are available.
Degree of protection -- IP67
Conforms to EN115-1; EN81-1 and EN81-2. (slow-action models only)
Certified standards -- UL; EN (TUV); and CCC
Location of origin
Japan
Degree of pollution
3 (as per EN60947-5-1)