OMRON
D4NH-8BBC
Safety-door hinge switch with arm lever act. + direct opening mechanism on NC contact - OMRON / STi (D4NH series) - 2NC (slow-action) contacts - 2 x term. wiring chamber with M20 condt. entries - IP67 - rated for -30...+70°C ambient - equivalent to D4NH8BBC
Please add this item to cart to request a quote or contact us at [email protected] for product availability.
Brand
SKU
D4NH-8BBC
Online Price
$79.00
Please add this item to cart to request a quote or contact us at [email protected] for product availability.
D4NH-8BBCOMRON - D4NH series
Description
Safety-door hinge switch with arm lever act. + direct opening mechanism on NC contact - OMRON / STi (D4NH series) - 2NC (slow-action) contacts - 2 x term. wiring chamber with M20 condt. entries - IP67 - rated for -30...+70°C ambient - equivalent to D4NH8BBC
Specifications
Primary brand
OMRON
Secondary brand
STi
Main function
Door switch (Hinge-operated)
Product series / family name
D4NH series
Network frequency
50/60 Hz
Functions
Safety-door hinge switch
Design
arm lever act.
direct opening mechanism on NC contact
direct opening mechanism on NC contact
Resistance (Ω)
25mΩ max. (contact resistance)
100mΩ min. (insulation resistance)
100mΩ min. (insulation resistance)
Distance
18° min. direct opening travel
2 x 2mm min. contact gap
2 x 2mm min. contact gap
Frequency
30 operations/minute max.
50/60Hz
50/60Hz
Rated current
10A (carry current; A300)
2.5A (carry current; Q300)
100A (conditional short-circuit; EN60947-5-1)
10A (Ith thermal current; EN 60547-5-1)
60A (make current; at 120Vac; A300)
6A (break current; at 120Vac; A300)
30A (make current; at 240Vac; A300)
3A (break current; at 240Vac; A300)
0.55A (make current; at 125Vdc; Q300)
0.55A (break current; at 125Vdc; Q300)
0.27A (make current; at 250Vdc; Q300)
0.27A (break current; at 250Vdc; Q300)
1mA (resistive load; at 5Vdc)
3A (AC-15)
0.27A (DC-13)
2.5A (carry current; Q300)
100A (conditional short-circuit; EN60947-5-1)
10A (Ith thermal current; EN 60547-5-1)
60A (make current; at 120Vac; A300)
6A (break current; at 120Vac; A300)
30A (make current; at 240Vac; A300)
3A (break current; at 240Vac; A300)
0.55A (make current; at 125Vdc; Q300)
0.55A (break current; at 125Vdc; Q300)
0.27A (make current; at 250Vdc; Q300)
0.27A (break current; at 250Vdc; Q300)
1mA (resistive load; at 5Vdc)
3A (AC-15)
0.27A (DC-13)
Rated operating voltage (Ue)
(AC-15) 240 V
(DC-13) 250 V
(DC-13) 250 V
Rated Voltage (DC)
125Vdc (Q300; 0.55A make current)
250Vdc (Q300; 0.27A make current)
250Vdc (Q300; 0.27A make current)
Rated voltage (AC)
120Vac (A300; 15A make current)
240Vac (A300; 7.5A make current)
240Vac (A300; 7.5A make current)
Rated impulse voltage (Uimp)
(between terminals of same polarity) 2.5 kV
(between terminals of different polarity) 4 kV
(between each terminal and non-current carrying metallic parts) 6 kV
(between terminals of different polarity) 4 kV
(between each terminal and non-current carrying metallic parts) 6 kV
Rated insulation voltage (Ui)
300 V
Connection type
2 x term. wiring chamber with M20 condt. entries
Protection functions
Class II electric shock protection (double insulation)
Speed
2...360°/s operating speed
Number of Normally Open (NO) circuits
0 NO Pole(s)
Number of Normally Closed (NC) circuits
2 NC Pole(s)
Contacts type
2NC (slow-action)
Degree of protection
IP67
Ambient air temperature for operation
-30...+70 °C
Force
1Nm min. direct opening force
Electrical durability (with load)
(3A resistive load at 250Vac) min. 500 000 operations
(10A resistive load at 250Vac) min. 300 000 operations
(10A resistive load at 250Vac) min. 300 000 operations
Mechanical durability (at no load)
min. 1 000 000 operations
Rated power
(make; A300) 7200 VA
(break; A300) 720 VA
(make-break; Q300) 69 VA
(break; A300) 720 VA
(make-break; Q300) 69 VA
Order code / Manufacturer SKU
D4NH-8BBC
Manufacturer product status
Commercialized
Equivalent to
D4NH8BBC
EAN code
4547648045636
Compliant with standard(s)
EN ISO 14119 - Type 1 - uncoded
EN 60947-5-1 (certified direct opening)
EN 50047
GS-ET-15
GB/T 14048.5
EN 60204-1
Vibration resistance - 10 to 55 Hz Single amplitude of 0.75mm
Shock resistance - 1000m/s2 min. (destruction)
Shock resistance - 300m/s2 min. (malfunction)
UL 508
CAN/CSA C22.2 No.14
EN 60947-5-1 (certified direct opening)
EN 50047
GS-ET-15
GB/T 14048.5
EN 60204-1
Vibration resistance - 10 to 55 Hz Single amplitude of 0.75mm
Shock resistance - 1000m/s2 min. (destruction)
Shock resistance - 300m/s2 min. (malfunction)
UL 508
CAN/CSA C22.2 No.14
Benefits
Lineup includes three contact models with 2NC/1NO and 3NC contact forms in addition to the previous contact forms 1NC/1NO; and 2NC. Models with MBB contacts are also available.
Can be used with both standard loads and microloads.
Can be used with both standard loads and microloads.
Location of origin
Japan
Degree of pollution
3 (as per EN60947-5-1)