OMRON
G3PW-A220EC-S-FLK
Single-phase power controller Solid State / Static Relay (SSR) with heater burnout detection - random AC load switching (instant-ON/OFF) - constant-current model - OMRON (G3PW series) - Input voltage 85-264Vac (100Vac-240Vac nom.) - 1A-20A rated current - single-pole / 1-pole (1P) - 85-264Vac (100Vac / 120Vac / 220Vac / 240Vac; 50/60Hz nom.) output voltage - term. connection with small slotted screws - Pnl. mounting / closed wall mounting - RS-485 communication capability - equivalent to G3PWA220ECSFLK
Please add this item to cart to request a quote or contact us at [email protected] for product availability.
Brand
SKU
G3PW-A220EC-S-FLK
Online Price
$565.00
Please add this item to cart to request a quote or contact us at [email protected] for product availability.
G3PW-A220EC-S-FLKOMRON - G3PW series
Description
Single-phase power controller Solid State / Static Relay (SSR) with heater burnout detection - random AC load switching (instant-ON/OFF) - constant-current model - OMRON (G3PW series) - Input voltage 85-264Vac (100Vac-240Vac nom.) - 1A-20A rated current - single-pole / 1-pole (1P) - 85-264Vac (100Vac / 120Vac / 220Vac / 240Vac; 50/60Hz nom.) output voltage - term. connection with small slotted screws - Pnl. mounting / closed wall mounting - RS-485 communication capability - equivalent to G3PWA220ECSFLK
Specifications
Primary brand
OMRON
Main function
Solid State Relay (SSR)
Product series / family name
Relays > Solid-state power controllers
Sub-range name
G3PW series
Functions
Single-phase power controller Solid State / Static Relay (SSR)
Design
heater burnout detection
random AC load switching (instant-ON/OFF)
constant-current model
random AC load switching (instant-ON/OFF)
constant-current model
Poles
single-pole / 1-pole (1P)
Resistance (Ω)
100MΩ min. (at 500Vdc) insulation resistance to ground
Rated current
1A-20A
Maximum inrush current 220A (1 cycle; 60Hz)
output OFF leakage current 10mA max. (at 100/110Vac)
output OFF leakage current 20mA max. (at 200/220Vac)
permissible I2t = 400A2s
Maximum inrush current 220A (1 cycle; 60Hz)
output OFF leakage current 10mA max. (at 100/110Vac)
output OFF leakage current 20mA max. (at 200/220Vac)
permissible I2t = 400A2s
Rated power
5VA max.
Rated voltage (AC)
85-264Vac (100Vac / 120Vac / 220Vac / 240Vac; 50/60Hz nom.)
output ON voltage drop 1.6V (RMS) max.
output ON voltage drop 1.6V (RMS) max.
Rated insulation voltage (Ui)
between charged parts and noncharged parts (50/60Hz; 1min.) 2500 V
Connection type
term. connection with small slotted screws
Control Voltage (AC)
85-264Vac (100Vac-240Vac nom.)
relay is guaranteed to close at 85Vac input and above
above 264Vac sustained voltage relay may face permanent coil damage
relay is guaranteed to close at 85Vac input and above
above 264Vac sustained voltage relay may face permanent coil damage
Communication protocol
RS-485
Mounting mode
Pnl. mounting / closed wall mounting
Speed
input response time (pick-up) 0-99.9s
input response time (drop-out) 0-99.9s
input response time (drop-out) 0-99.9s
Dimensions
H170mm x W50mm x D136.5mm
Ambient air temperature for operation
-15...+55 °C
Mechanical resistance
10 to 55Hz; 100 m/s2 vibration resistance
300m/s2 shock resistance
300m/s2 shock resistance
Order code / Manufacturer SKU
G3PW-A220EC-S-FLK
Manufacturer product status
Commercialized
Equivalent to
G3PWA220ECSFLK
EAN code
4547648600460
Compliant with standard(s)
CE
cURus
UL
TUV
cURus
UL
TUV
Benefits
High-precision control with easy setup
Precise heater burnout detection
Set value and present value monitoring with indicators
Phase control or optimum cycle control
RS-485 communications to set manipulated variables and monitor load current
Total run time monitoring
Output modes for phase control are proportional to phase angle / proportional to voltage / proportional to square voltage and constant-current control
Application with various loads / constant load resistance / variable load resistance
UL and IEC/EN (TUV) certified
Precise heater burnout detection
Set value and present value monitoring with indicators
Phase control or optimum cycle control
RS-485 communications to set manipulated variables and monitor load current
Total run time monitoring
Output modes for phase control are proportional to phase angle / proportional to voltage / proportional to square voltage and constant-current control
Application with various loads / constant load resistance / variable load resistance
UL and IEC/EN (TUV) certified
Related Documents
Name | Last Update | Language |
---|---|---|
OMRON - G3PW series - Datasheet.pdf | 10 Jan 2023 | English (US) |