OMRON
G9SE-221-T05
Complete safety relay compact unit with status indicator + 2 OFF-delay outputs - PL.e / Cat4 - OMRON / STi (G9SE series) - with 5s max. OFF delayed time - with 1 x safety input 1 (T11; T12) + 1 x safety input 2 (T21; T22) + 1 x feedback/reset input (T31; T32; T33) + 1 x pow. suppl. input (A1-A2) + 1 x instantaneous safety output (DPST each with 2NO contacts in series) (13-14; 23-24) + 1 x OFF-delayed output (DPST each with 2NO contacts in series) (37-38; 47-48) + 1 x aux. output (PNP; 100mA) (X1) - 24Vdc / 24Vac (50/60Hz) supply voltage - DIN rail mounting - IP20 - rated for -10...+55°C ambient - equivalent to G9SE221T05
Please add this item to cart to request a quote or contact us at [email protected] for product availability.
Brand
SKU
G9SE-221-T05
Online Price
$335.00
Please add this item to cart to request a quote or contact us at [email protected] for product availability.
G9SE-221-T05OMRON - G9SE series
Description
Complete safety relay compact unit with status indicator + 2 OFF-delay outputs - PL.e / Cat4 - OMRON / STi (G9SE series) - with 5s max. OFF delayed time - with 1 x safety input 1 (T11; T12) + 1 x safety input 2 (T21; T22) + 1 x feedback/reset input (T31; T32; T33) + 1 x pow. suppl. input (A1-A2) + 1 x instantaneous safety output (DPST each with 2NO contacts in series) (13-14; 23-24) + 1 x OFF-delayed output (DPST each with 2NO contacts in series) (37-38; 47-48) + 1 x aux. output (PNP; 100mA) (X1) - 24Vdc / 24Vac (50/60Hz) supply voltage - DIN rail mounting - IP20 - rated for -10...+55°C ambient - equivalent to G9SE221T05
Specifications
Primary brand
OMRON
Secondary brand
STi
Main function
Safety relay
Product series / family name
G9SE series
Functions
Complete safety relay compact unit
Design
status indicator
2 OFF-delay outputs
2 OFF-delay outputs
Resistance (Ω)
100mΩ (contact resistance; measured with 1A at 5Vdc using voltage drop method)
100mΩ min. (insulation resistance)
100mΩ min. (insulation resistance)
Supply voltage (AC)
24Vac (50/60Hz)
Supply voltage (DC)
24Vdc
Rated current
5A (resistive load; rated load; 250Vac; 30Vdc)
1.5A (2Vdc; DC-13)
2A (240Vac; AC-15)
4mA (minimum applicable load; at 24Vdc)
100A (conditional short-circuit current; IEC/EN 60947-5-1)
5mA (min. input current)
1mA max. (OFF current)
1.5A (2Vdc; DC-13)
2A (240Vac; AC-15)
4mA (minimum applicable load; at 24Vdc)
100A (conditional short-circuit current; IEC/EN 60947-5-1)
5mA (min. input current)
1mA max. (OFF current)
Rated voltage (AC)
2200Vac (for 1 min.; dielectric strength; between input and output)
1500Vac (dielectric strength; between different poles of output)
1500Vac (dielectric strength; between different poles of output)
Rated impulse voltage (Uimp)
(between input and output) 6 kV
(between 13-14 (23-24) / 33-34 (37-38) / 43-44 (47-48)) 6 kV
(between 13-14 (23-24) / 33-34 (37-38) / 43-44 (47-48)) 4 kV
(between 13-14 (23-24) / 33-34 (37-38) / 43-44 (47-48)) 6 kV
(between 13-14 (23-24) / 33-34 (37-38) / 43-44 (47-48)) 4 kV
Rated insulation voltage (Ui)
(isolation voltage; AC) 250 V
Length
100m max. cable
Mounting mode
DIN rail
Digital inputs
1 x safety input 1 (T11; T12)
1 x safety input 2 (T21; T22)
1 x feedback/reset input (T31; T32; T33)
1 x pow. suppl. input (A1-A2)
1 x safety input 2 (T21; T22)
1 x feedback/reset input (T31; T32; T33)
1 x pow. suppl. input (A1-A2)
Digital outputs
1 x instantaneous safety output (DPST each with 2NO contacts in series) (13-14; 23-24)
1 x OFF-delayed output (DPST each with 2NO contacts in series) (37-38; 47-48)
1 x aux. output (PNP; 100mA) (X1)
1 x OFF-delayed output (DPST each with 2NO contacts in series) (37-38; 47-48)
1 x aux. output (PNP; 100mA) (X1)
Response time
(OFF=>ON; normal operation; not include bounce time) max. 100ms / max. 0.1 s
(OFF=>ON; include bounce time) max. 15ms / max. 0.015 s
(RESET input time) min. 250ms / min. 0.25 s
(OFF=>ON; include bounce time) max. 15ms / max. 0.015 s
(RESET input time) min. 250ms / min. 0.25 s
Degree of protection
IP20
Ambient air temperature for operation
-10...+55 °C
Power consumption
max. 4 W
Electrical durability (with load)
min. 50 000 operations
Mechanical durability (at no load)
min. 5 000 000 operations
Rated breaking capacity
(with IEC60127-compliant 8A fuse) 100 kA
Order code / Manufacturer SKU
G9SE-221-T05
Manufacturer product status
Commercialized
Equivalent to
G9SE221T05
EAN code
4548583535756
Compliant with standard(s)
IEC/EN 60664-1 - II (over-voltage category)
IEC/EN 60664-1 - III (safety output; over-voltage category)
Vibration resistance - 10 to 55 Hz Half amplitude of 0.35mm (Double amplitude of 0.7mm)
Shock resistance - 300m/s2 min. (destruction)
Shock resistance - 100m/s2 min. (malfunction)
IEC/EN 60664-1 - III (safety output; over-voltage category)
Vibration resistance - 10 to 55 Hz Half amplitude of 0.35mm (Double amplitude of 0.7mm)
Shock resistance - 300m/s2 min. (destruction)
Shock resistance - 100m/s2 min. (malfunction)
Class
PL.e / Cat4
Location of origin
China
Degree of pollution
2
Application type
The OFF-delayed output becomes an instantaneous output by setting the OFF-delay time to 0s
Time delay
5s max. OFF delayed time
0s / 0.1s / 0.2s / 0.3s / 0.4s / 0.5s / 0.6s / 0.7s / 0.8s / 1s / 1.5s / 2s / 2.5s / 3s / 4s / 5s configurable OFF delayed time
0s / 0.1s / 0.2s / 0.3s / 0.4s / 0.5s / 0.6s / 0.7s / 0.8s / 1s / 1.5s / 2s / 2.5s / 3s / 4s / 5s configurable OFF delayed time
Time delay
(OFF-delay - adjustable) 0-5 s
(OFF => ON) 0.1 s
(ON => OFF) 0.015 s
(OFF => ON) 0.1 s
(ON => OFF) 0.015 s